[Code of Federal Regulations]
[Title 16, Volume 2]
[Revised as of January 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 16CFR1211.15]

[Page 337-338]
 
                     TITLE 16--COMMERCIAL PRACTICES
 
             CHAPTER II--CONSUMER PRODUCT SAFETY COMMISSION
 
PART 1211_SAFETY STANDARD FOR AUTOMATIC RESIDENTIAL GARAGE DOOR 
OPERATORS--Table of Contents
 
                         Subpart A_The Standard
 
Sec.  1211.15  Field-installed labels.

    (a) A residential garage door operator shall be provided with labels 
for field installation and constructed as specified in paragraphs (c) 
through (i) of this section. The labels shall be acceptable for 
permanent installation. The instruction manual shall specify where the 
labels are to be located.
    (b) If labels secured by adhesive are used, the instruction shall 
specify that an additional mechanical means shall be used to secure the 
labels to surfaces to which the adhesive will not adhere.
    (c) A residential garage door operator shall be provided with a 
cautionary label intended for permanent installation to identify the 
possible risk of entrapment. The instruction manual shall direct that 
the label be affixed near the wall-mounted control button.
    (d) The label required in accordance with paragraph (c) of this 
section shall be in a vertical layout with three panels:
    (1) A signal word panel,
    (2) A pictorial panel, and
    (3) A message panel, with adjacent panels delineated from each other 
by a horizontal black line. The entire label shall be surrounded by a 
black border and shall measure at least 5 inches (127 mm) wide by 6\1/4\ 
inches (159 mm) long overall.
    (e) The signal word panel as specified in paragraph (d) of this 
section shall contain the word ``WARNING,'' in uppercase letters, 
preceded by a safety alert symbol consisting of an orange exclamation 
mark on a black solid equilateral triangle background with the point of 
the triangle oriented upward. The word ``WARNING'' and the safety alert 
symbol shall be centered on one line and shall be in black letters at 
least \7/16\ inch (11.1 mm) high on an orange background.
    (f) The pictorial panel as specified in paragraph (d) of this 
section shall be positioned between the signal word panel and the 
message panel. The pictorial shall be black on a white background and 
shall clearly depict a child running toward or under a garage door.

[[Page 338]]

A red prohibition symbol (slash, oriented from the upper left to the 
lower right, through a circle) shall be superimposed over, and totally 
surround, the pictorial. The pictorial shall have an overall diameter of 
1-7\1/8\ inch (47.6 mm) minimum.
    (g) The message panel as specified in paragraph (d) of this section 
shall include the following text or an equivalent wording:
    (1) Possible Risk and Consequence Statement--``There is a risk of a 
child becoming trapped under an automatic garage door resulting in 
severe injury or death.''
    (2) Avoidance Statements--
    (i) ``Do not allow children to walk or run under a closing door.''
    (ii) ``Do not allow children to operate door operator controls.''
    (iii) ``Always keep a closing door within sight.''
    (iv) ``In the event a person is trapped under the door, push the 
control button or use the emergency release.'' For products not having 
an emergency release use instead ``In the event a person is trapped 
under the door, push the control button.''
    (3) Instructions--
    (i) ``Test Door Operator Monthly: Use a 1\1/2\ inch thick object 
placed on the floor under the closing door. In the event the door does 
not reverse upon contact, adjust, repair, or replace the operator.''
    (ii) Additional instructions on not removing or painting over the 
label, mounting the label adjacent to the wall control, and mounting the 
wall control out of children's reach shall be provided. These additional 
instruction shall be in less prominent lettering than those in paragraph 
(g)(3)(i) of this section.
    (h) The lettering of the message panel described in paragraph (g) of 
this section shall be black on a white background and shall be sans 
serif letters in combinations of upper case and lower case letters. The 
upper case letters of the Possible Risk and Consequence Statements and 
Avoidance Statements shall be \1/8\ inch (3.18 mm) high minimum. The 
lettering of the Possible Risk and Consequence Statement shall be in 
italics, underlined, bold, or the like, and shall be double spaced from 
the Avoidance Statements. All other instructions shall be in letters 
less prominent than the Possible Risk and Consequence Statements and 
shall be separated with at least a single space between individual 
instructions.
    (i) Except for door operators complying with Sec.  1211.9(b), a 
residential garage door operator shall be provided with a cautionary 
marking attached to or adjacent at all times to the means provided to 
detach the operator from the garage door. The marking shall include the 
following statement or the equivalent: ``If the door becomes obstructed, 
detach door from operator as follows: (The method to detach the operator 
shall be shown on the marking.)''

[57 FR 60455, Dec. 21, 1992. Redesignated and amended at 65 FR 70659, 
Nov. 27, 2000]