[Code of Federal Regulations]
[Title 16, Volume 2]
[Revised as of January 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 16CFR1630.3]

[Page 697]
 
                     TITLE 16--COMMERCIAL PRACTICES
 
             CHAPTER II--CONSUMER PRODUCT SAFETY COMMISSION
 
PART 1630_STANDARD FOR THE SURFACE FLAMMABILITY OF CARPETS AND RUGS 
(FF 1-70)--Table of Contents
 
                         Subpart A_The Standard
 
Sec.  1630.3  General requirements.

    (a) Summary of test method. This method involves the exposure of 
each of eight conditioned, replicate specimens of a given carpet or rug 
to a standard igniting source in a draft-protected environment, and 
measurement of the proximity of the charred portion to the edge of the 
hole in the prescribed flattening frame.
    (b) Test criterion. A specimen passes the test if the charred 
portion does not extend to within 2.54 cm. (1.0 in.) of the edge of the 
hole in the flattening frame at any point.
    (c) Acceptance criterion. At least seven of the eight specimens 
shall meet the test criterion in order to conform with this Standard.