[Code of Federal Regulations] [Title 40, Volume 31] [Revised as of July 1, 2007] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR1065.202] [Page 700-701] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 1065_ENGINE-TESTING PROCEDURES--Table of Contents Subpart C_Measurement Instruments Sec. 1065.202 Data updating, recording, and control. Your test system must be able to update data, record data and control systems related to operator demand, the dynamometer, sampling equipment, and measurement instruments. Use data acquisition and control systems that can record at the specified minimum frequencies, as follows: [[Page 701]] Table 1 of Sec. 1065.202--Data Recording and Control Minimum Frequencies ---------------------------------------------------------------------------------------------------------------- Minimum command and Minimum recording Applicable test protocol section Measured values control frequency frequency ---------------------------------------------------------------------------------------------------------------- Sec. 1065.510.................... Speed and torque during an 1 Hz.................. 1 mean value per step. engine step-map. Sec. 1065.510.................... Speed and torque during an 5 Hz.................. 1 Hz means. engine sweep-map. Sec. 1065.514, Sec. 1065.530... Transient duty cycle 5 Hz.................. 1 Hz means. reference and feedback speeds and torques. Sec. 1065.514, Sec. 1065.530... Steady-state and ramped- 1 Hz.................. 1 Hz. modal duty cycle reference and feedback speeds and torques. Sec. 1065.520, Sec. 1065.530, Continuous concentrations N/A................... 1 Hz. Sec. 1065.550. of raw or dilute analyzers. Sec. 1065.520, Sec. 1065.530, Batch concentrations of raw N/A................... 1 mean value per test Sec. 1065.550. or dilute analyzers. interval. Sec. 1065.530, Sec. 1065.545... Diluted exhaust flow rate N/A................... 1 Hz. from a CVS with a heat exchanger upstream of the flow measurement. Sec. 1065.530, Sec. 1065.545... Diluted exhaust flow rate 5 Hz.................. 1 Hz means. from a CVS without a heat exchanger upstream of the flow measurement. Sec. 1065.530, Sec. 1065.545... Intake-air or raw-exhaust N/A................... 1 Hz means. flow rate. Sec. 1065.530, Sec. 1065.545... Dilution air if actively 5 Hz.................. 1 Hz means. controlled. Sec. 1065.530.................... Sample flow from a CVS that 1 Hz.................. 1 Hz. has a heat exchanger. Sec. 1065.530, Sec. 1065.545... Sample flow from a CVS does 5 Hz.................. 1 Hz mean. not have a heat exchanger. ----------------------------------------------------------------------------------------------------------------