[Code of Federal Regulations] [Title 40, Volume 29] [Revised as of July 1, 2007] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR429.31] [Page 88-89] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 429_TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY --Table of Contents Subpart B_Veneer Subcategory Sec. 429.31 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by application of the best practicable control technology currently available (BPT): (a) The following limitations constitute the maximum permissible discharge for all veneer manufacturing installations other than those referred to in paragraphs (b) and (c) of this section: There shall be no discharge of process wastewater pollutants into navigable waters. (b) The following limitations constitute the maximum permissible discharge for softwood veneer manufacturing processes which use direct steaming for the conditioning of logs: [[Page 89]] Subpart B ------------------------------------------------------------------------ BPT effluent limitations ------------------------- Average of daily Pollutant or pollutant property values for Maximum for 30 any 1 day consecutive days shall not exceed ------------------------------------------------------------------------ Metric units (kilograms per cubic meter of production) ------------------------- BOD5.......................................... 0.72 0.24 pH............................................ (\1\) (\1\) ------------------------- English units (pounds per cubic foot of production) ------------------------- BOD5.......................................... 0.045 0.015 pH............................................ (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0 at all times. (c) The following limitations constitute the maximum permissible discharge for hardwood veneer manufacturing processes which use direct steaming for the conditioning of logs: Subpart B ------------------------------------------------------------------------ BPT effluent limitations ------------------------- Average of daily Pollutant or pollutant property values for Maximum for 30 any 1 day consecutive days shall not exceed ------------------------------------------------------------------------ Metric units (kilograms per cubic meter of production) ------------------------- BOD5.......................................... 1.62 0.54 pH............................................ (\1\) (\1\) ------------------------- English units (pounds per cubic foot of production) ------------------------- BOD5.......................................... 0.10 0.034 pH............................................ (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0 at all times.