[Code of Federal Regulations] [Title 40, Volume 29] [Revised as of July 1, 2007] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR434.22] [Page 278-279] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 434_COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS--Table of Contents Subpart B_Coal Preparation Plants and Coal Preparation Plant Associated Areas Sec. 434.22 Effluent limitation guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). (a) Except as provided in 40 CFR 125.30-125.32, 40 CFR 401.17, and Sec. Sec. 434.61, 434.62 and 434.63 of this part, the following limitations establish the concentration or quality of pollutants which may be discharged by any existing coal preparation plant and coal preparation plant associated areas subject to the provisions of this subpart after application of the best practicable control technology currently available if discharges from such point sources normally exhibit a pH of less than 6.0 prior to treatment: BPT Effluent Limitations ------------------------------------------------------------------------ Average of daily values Pollutant or pollutant property Maximum for for 30 any 1 day consecutive days ------------------------------------------------------------------------ Concentration in mg/l --------------------------- Iron, total................................. 7.0 3.5 Manganese, total............................ 4.0 2.0 TSS......................................... 70 35 pH.......................................... \1\ \1\ ------------------------------------------------------------------------ \1\ Within the range of 6.0 to 9.0 at all times. (b) Except as provided in 40 CFR 125.30-125.32, 40 CFR 401.17 and Sec. Sec. 434.61 and 434.63 of this part, the following limitations establish the concentration or quality of pollutants which may be discharged by any existing coal preparation plant and coal preparation plant associated areas subject to the provisions of this subpart after application of the best practicable control technology currently available if discharges from such point sources normally exhibit a pH equal to or greater than 6.0 prior to treatment: [[Page 279]] BPT Effluent Limitations ------------------------------------------------------------------------ Average of daily values Pollutant or pollutant property Maximum for for 30 any 1 day consecutive days ------------------------------------------------------------------------ Concentration in mg/l --------------------------- Iron, total................................. 7.0 3.5 TSS......................................... 70 35 pH.......................................... \1\ \1\ ------------------------------------------------------------------------ \1\ Within the range of 6.0 to 9.0 at all times.