[Code of Federal Regulations] [Title 40, Volume 29] [Revised as of July 1, 2007] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR434.42] [Page 281] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 434_COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS--Table of Contents Subpart D_Alkaline Mine Drainage Sec. 434.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30-125.32, 40 CFR 401.17, and Sec. Sec. 434.61 and 434.63 of this part, the following limitations establish the concentration or quality of pollutants which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available: BPT Effluent Limitations ------------------------------------------------------------------------ Average of daily values Pollutant or pollutant property Maximum for for 30 any 1 day consecutive days ------------------------------------------------------------------------ Concentration in mg/l --------------------------- Iron, total................................. 7.0 3.5 TSS......................................... 70. 35. pH.......................................... (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0 at all times.