[Code of Federal Regulations]
[Title 40, Volume 29]
[Revised as of July 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR465.15]

[Page 600]
 
                   TITLE 40--PROTECTION OF ENVIRONMENT
 
         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 465_COIL COATING POINT SOURCE CATEGORY--Table of Contents
 
               Subpart A_Steel Basis Material Subcategory
 
Sec. 465.15  Pretreatment standards for new sources.

    Except as provided in CFR 403.7, any new source subject to this 
subpart which introduces pollutants into a publicly owned treatment 
works must comply with 40 CFR part 403 and achieve the following 
pretreatment standards for new sources. The mass of wastewater 
pollutants in coil coating process wastewater introduced into a POTW 
shall not exceed the following values:

                                Subpart A
------------------------------------------------------------------------
                                                    PSNS
                                   -------------------------------------
                                    Maximum for any 1     Maximum for
  Pollutant or pollutant property          day          monthly average
                                   -------------------------------------

------------------------------------------------------------------------
                                      mg/m \2\ (pounds per 1 million ft
                                           \2\) of area processed
                                   -------------------------------------
Chromium..........................     0.12   (0.024)     0.047  (0.01)
Cyanide...........................     0.063  (0.013)     0.025  (0.005)
Zinc..............................     0.33   (0.066)     0.14   (0.027)
------------------------------------------------------------------------


[47 FR 54244, Dec. 1, 1982; 49 FR 33648, Aug. 24, 1984]