[Code of Federal Regulations]
[Title 46, Volume 1]
[Revised as of January 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR25.30-20]

[Page 315-317]
 
                           TITLE 46--SHIPPING
 
         CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
 
PART 25_REQUIREMENTS--Table of Contents
 
               Subpart 25.30_Fire Extinguishing Equipment
 
Sec. 25.30-20  Fire extinguishing equipment required.

    (a) Motorboats. (1) All motorboats shall carry at least the minimum 
number of hand portable fire extinguishers set forth in Table 25.30-
20(a)(1), except that motorboats less than 26 feet in length, propelled 
by outboard motors and not carrying passengers for hire, need not carry 
such portable fire extinguishers if the construction of such motorboats 
will not permit the entrapment of explosive or flammable gases or 
vapors.

[[Page 316]]



                          Table 25.30-20(a)(1)
------------------------------------------------------------------------
                                            Minimum number of B-1 hand
                                            portable fire extinguishers
                                                   required \1\
                                         -------------------------------
              Length, feet                 No fixed fire    Fixed fire
                                           extinguishing   extinguishing
                                             system in       system in
                                             machinery       machinery
                                               space           space
------------------------------------------------------------------------
Under 16................................               1               0
16 and over, but under 26...............               1               0
26 and over, but under 40...............               2               1
40 and over, but not over 65............               3               2
------------------------------------------------------------------------
\1\ One B-11 hand portable fire extinguisher may be substituted for two
  B-I hand portable fire extinguishers.

    (2) The intent of this regulation is illustrated in Figure 25.30-
20(a1) where fire extinguishers are required if any one or more of the 
specified conditions exist, and in Figure 25.30-20(a2) where specified 
conditions do not, in themselves, require that fire extinguishers be 
carried.
[GRAPHIC] [TIFF OMITTED] TC01FE91.066

                           Figure 25.30-20(a1)
    Fire extinguishers are required if any one or more of the following 
conditions exist (numbers identifying conditions are the same as those 
placed in Figure 25.30-20 (a1)):
    1. Closed compartment under thwarts and seats wherein portable fuel 
tanks may be stored.
    2. Double bottoms not sealed to the hull or which are not completely 
filled with flotation material.
    3. Close living spaces.
    4. Closed stowage compartments in which combustible or flammable 
materials are stowed.
    5. Permanently installed fuel tanks.
    [GRAPHIC] [TIFF OMITTED] TC01FE91.067
    
                           Figure 25.30-20(a2)
    The following conditions do not, in themselves, require that fire 
extinguishers be carried (numbers identifying conditions are the same as 
those placed in Figure 25.30-20(a2)):
    1. Bait wells.
    2. Glove compartments.
    3. Buoyant flotation material.
    4. Open slatted flooring.
    5. Ice chests.

    (b) Uninspected passenger vessels of at least 100 gross tons. All 
uninspected passenger vessels of at least 100 gross tons must carry 
onboard hand-portable and semi-portable fire extinguishers per Table 
76.50-10(a) in Sec. 76.50-10 of this chapter.
    (c) Motor vessels. (1) All motor vessels shall carry at least the 
minimum number of hand portable fire extinguishers set forth in Table 
25.30-20(b) (1).

                          Table 25.30-20(b)(1)
------------------------------------------------------------------------
            Gross tonnage--
----------------------------------------   Minimum number of B-II hand
            Over               Not over    portable fire extinguishers
------------------------------------------------------------------------
                                     50                 1
50..........................        100                 2
100.........................        500                 3
500.........................      1,000                 6
1,000.......................  .........                 8
------------------------------------------------------------------------

    (2) In addition to the hand portable fire extinguishers required by 
paragraph (b)(1) of this section, the following fire-extinguishing 
equipment shall be fitted in the machinery space:
    (i) One Type B-II hand portable fire extinguisher shall be carried 
for each 1,000 B. H. P. of the main engines or fraction thereof. 
However, not more than 6 such extinguishers need be carried.
    (ii) On motor vessels of over 300 gross tons, either one Type B-III 
semiportable fire-extinguishing system shall be fitted, or 
alternatively, a fixed fire-extinguishing system shall be fitted in the 
machinery space.
    (3) The frame or support of each Type B-III fire extinguisher 
required by paragraph (b)(2)(ii) of this section must be welded or 
otherwise permanently attached to a bulkhead or deck.
    (4) If an approved semiportable fire extinguisher has wheels and is 
not required by this section, it must be securely stowed when not in use 
to prevent it from rolling out of control under heavy sea conditions.
    (d) Barges carrying passengers. (1) Every barge of 65 feet in length 
or less while carrying passengers when towed or pushed by a motorboat, 
motor vessel, or steam vessel shall be fitted with

[[Page 317]]

hand portable fire extinguishers as required by Table 25.30-20(a)(1), 
depending upon the length of the barge.
    (2) Every barge of over 65 feet in length while carrying passengers 
when towed or pushed by a motorboat, motor vessel, or steam vessel shall 
be fitted with hand portable fire extinguishers as required by Table 
25.30-20(b)(1), depending upon the gross tonnage of the barge.

[CGFR 65-50, 30 FR 16653, Dec. 30, 1965, as amended by CGD 77-039, 44 FR 
34132, June 14, 1979; CGD 97-057, 62 FR 51042, Sept. 30, 1997; USCG-
1999-5040, 67 FR 34776, May 15, 2002]