[Code of Federal Regulations] [Title 46, Volume 1] [Revised as of January 1, 2007] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR34.50-15] [Page 469] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PART 34_FIREFIGHTING EQUIPMENT--Table of Contents Subpart 34.50_Portable and Semiportable Extinguishers Sec. 34.50-15 Spare charges--TB/ALL. (a) Spare charges shall be carried on all vessels for at least 50 percent of each size and each variety, i.e. foam, soda-acid, carbon dioxide, etc., of portable extinguisher required by Sec. 34.50-10(a). However, if the unit is of such variety that it cannot be readily recharged by the vessel's personnel, one spare unit of the same classification shall be carried in lieu of spare charges for all such units of the same size and variety. This section does not apply to unmanned barges. (b) Spare charges shall be so packaged as to minimize the hazards to personnel while recharging the units. [[Page 470]]