[Code of Federal Regulations]
[Title 47, Volume 2]
[Revised as of October 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 47CFR73.57]

[Page 24-25]
 
                       TITLE 47--TELECOMMUNICATION
 
        CHAPTER I--FEDERAL COMMUNICATIONS COMMISSION (CONTINUED)
 
PART 73_RADIO BROADCAST SERVICES--Table of Contents
 
                     Subpart A_AM Broadcast Stations
 
Sec.  73.57  Remote reading antenna and common point ammeters.

    Remote reading antenna and common point ammeters may be used without 
further authority according to the following conditions:
    (a) Remote reading antenna or common point ammeters may be provided 
by:
    (1) Inserting second radio frequency current sensing device directly 
in the antenna circuit with remote leads to the indicating instruments.
    (2) Inductive coupling to radio frequency current sensing device for 
providing direct current to indicating instrument.
    (3) Capacity coupling to radio frequency current sensing device for 
providing direct current to indicating instrument.
    (4) Current transformer connected to radio frequency current sensing 
device for providing direct current to indicating instrument.

[[Page 25]]

    (5) Using transmission line current meter at transmitter as remote 
reading ammeter. See paragraph (c) of this section.
    (6) Using the indications of the antenna (phase) monitor, provided 
that when the monitor is used to obtain remote reading indication of 
non-directional antenna base current, the monitor calibration can be 
independently made and maintained for each mode of operation.
    (b) Devices used for obtaining remote reading antenna or common 
point current indications, except antenna monitor coupling elements, 
shall be located at the same point as, but below (transmitter side) the 
associated main ammeter.
    (c) In the case of shunt-excited antennas, the transmission line 
current meter at the transmitter may be considered as the remote antenna 
ammeter provided the transmission line is terminated directly into the 
excitation circuit feed line, which shall employ series tuning only (no 
shunt circuits of any type shall be employed) and insofar as 
practicable, the type and scale of the transmission line meter should be 
the same as those of the excitation circuit feed line meter (meter in 
slant wire feed line or equivalent).
    (d) Each remote reading ammeter shall be accurate to within 2 
percent of the value read on its corresponding regular ammeter.
    (e) All remote reading ammeters shall conform with the 
specifications for regular antenna ammeters.
    (f) Meters with arbitrary scale divisions may be used provided that 
calibration charts or curves are provided at the transmitter control 
point showing the relationship between the arbitrary scales and the 
reading of the main meters.
    (g) If a malfunction affects the remote reading indicators of the 
antenna or common point ammeter, the operating power may be determined 
by a method using alternative procedures as described in Sec.  73.51.

[41 FR 36817, Sept. 1, 1976, as amended at 48 FR 38477, Aug. 24, 1983; 
49 FR 49850, Dec. 24, 1984; 50 FR 32416, Aug. 12, 1985; 60 FR 55480, 
Nov. 1, 1995]