Sec.  229.31  Main reservoir tests.

    (a) Before it is placed in service, each main reservoir other than 
an aluminum reservoir shall be subjected to a pneumatic or hydrostatic 
pressure of at least 25 percent more than the maximum working pressure 
fixed by the chief mechanical officer. The test date, place, and 
pressure shall be recorded on Form FRA F 6180-49A, block eighteen. 
Except as provided in paragraph (c) of this section, at intervals that 
do not exceed 736 calendar days, each main reservoir other than an 
aluminum reservoir shall be subjected to a hydrostatic pressure of at 
least 25 percent more than the maximum working pressure fixed by the 
chief mechanical officer. The test date, place, and pressure shall be 
recorded on Form FRA F 6180-49A, and the person performing the test and 
that person's supervisor shall sign the form.
    (b) Except as provided in paragraph (c) of this section, each main 
reservoir other than an aluminum reservoir shall be hammer tested over 
its entire surface while the reservoir is empty at intervals that do not 
exceed 736 calendar days. The test date and place shall be

[[Page 430]]

recorded on Form FRA F 6180-49A, and the person performing the test and 
that person's supervisor shall sign the form.
    (c) Each welded main reservoir originally constructed to withstand 
at least five times the maximum working pressure fixed by the chief 
mechanical officer may be drilled over its entire surface with telltale 
holes that are three-sixteenths of an inch in diameter. The holes shall 
be spaced not more than 12 inches apart, measured both longitudinally 
and circumferentially, and drilled from the outer surface to an extreme 
depth determined by the formula--

D = (.6PR/S-0.6P)

Where:

D = extreme depth of telltale holes in inches but in no case less than 
          one-sixteenth inch;
P = certified working pressure in pounds per square inch;
S = one-fifth of the minimum specified tensile strength of the material 
          in pounds per square inch; and
R = inside radius of the reservoir in inches.

    One row of holes shall be drilled lengthwise of the reservoir on a 
line intersecting the drain opening. A reservoir so drilled does not 
have to meet the requirements of paragraphs (a) and (b) of this section, 
except the requirement for a pneumatic or hydrostatic test before it is 
placed in use. Whenever any such telltale hole shall have penetrated the 
interior of any reservoir, the reservoir shall be permanently withdrawn 
from service. A reservoir now in use may be drilled in lieu of the tests 
provided for by paragraphs (a) and (b) of this section, but shall 
receive a hydrostatic test before it is returned to use or may receive a 
pneumatic test if conducted by the manufacturer in an appropriately safe 
environment.
    (d) Each aluminum main reservoir before being placed in use and at 
intervals that do not exceed 736 calendar days thereafter, shall be--
    (1) Cleaned and given a thorough visual inspection of all internal 
and external surfaces for evidence of defects or deterioration; and
    (2) Subjected to a hydrostatic pressure at least twice the maximum 
working pressure fixed by the chief mechanical officer, but not less 
than 250 p.s.i. The test date, place, and pressure shall be recorded on 
Form FRA F 6180-49A, and the person conducting the test and that 
person's supervisor shall sign the form.

[45 FR 21109, Mar. 31, 1980, as amended at 71 FR 61857, Oct. 19, 2006]