[Code of Federal Regulations]
[Title 9, Volume 2]
[Revised as of January 1, 2008]
From the U.S. Government Printing Office via GPO Access
[CITE: 9CFR307.7]

[Page 105-106]
 
                  TITLE 9--ANIMALS AND ANIMAL PRODUCTS
 
     CHAPTER III--FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF 
                               AGRICULTURE
 
PART 307_FACILITIES FOR INSPECTION--Table of Contents
 
Sec. 307.7  Safety requirements for electrical stimulating (EST) equipment.

    (a) General. Electrical stimulating (EST) equipment is equipment 
that provides electric shock treatment to carcasses for the purpose of 
accelerating rigor mortis of facilitating blood removal. These 
provisions do not apply to electrical equipment used to stun and/or 
slaughter animals or to facilitate hide removal. Electrical stimulating 
equipment consists of two separate pieces--the control system and the 
applicator. The EST control system contains the circuitry to generate 
pulsed DC or AC voltage for stimulation and is separate from the 
equipment used to apply the voltage to the carcass. The voltage is 
applied by inserting a probe that penetrates the carcass or is inserted 
in the rectum, placing a clamp in the nose, a carcass rub-bar, a 
conveyor with energized surfaces traveling with the carcass, or any 
other acceptable method.
    (b) Safety requirements--(1) Circuits, grounding. Either a bonded 
grounding conductor shall lead from each section of the carcass rail 
within the stimulating enclosure to the service ground, or the secondary 
voltage (stimulating circuit) shall be insulated from the service 
ground. If the stimulating section of the carcass rail and carcass drive 
mechanisms are insulated from the service ground then the stimulating 
rail or the return path shall be electrically bonded to the transformer 
secondary to isolate the stimulation voltage.
    (2) Enclosure. Electrical stimulation shall occur in an area that 
will prevent persons from contacting an energized surface. If the area 
is surrounded by physical barriers, the enclosure shall be either 
electrically grounded or it shall be made of materials that do not 
conduct electricity. The interior of the stimulating area shall be 
visible from the start switch so the operator can be assured that there 
is no person, equipment or material present that should not be there 
prior to starting the stimulating sequence. If light or sound beam 
sensors form the enclosure, the stimulating equipment shall be 
automatically shut off when the sensor signals are broken.
    (3) Mandatory Warning Devices and Signals. The following warning 
devices or signals shall be installed at each opening to the stimulating 
area through which a person would normally enter:
    (i) A red light that flashes distinctly during the operating cycle 
of the stimulating equipment.
    (ii) An ANSI Z53.1-Color Code sign reading (a) ``Danger Electrical 
Hazard'' for stimulating voltage below 50 or (b) ``Danger High Voltage'' 
for stimulating voltage above 50.
    (iii) An emergency stop button.
    (4) Optional Warning Device--Horn or Bell. If a warning horn or bell 
is installed, the signal shall be audible above background noises in the 
vicinity, and it shall sound for at least 1 second before each manual 
stimulation or before the carcass chain is started in an automatic 
system.
    (c) Operation--
    (1) Training. Only persons who have received safety instruction by 
the equipment manufacturer or designee may operate electrical 
stimulating equipment.
    (2) Cleaning and Maintenance. To prevent an electrical shock to 
personnel,

[[Page 106]]

the electricity supplied to the stimulating surfaces shall be locked-off 
when cleaning, mechanical inspection, maintenance or testing are 
performed.
    (3) Water. To prevent an electrical shock, personnel shall not spray 
streams of water on energized carcasses or on energized stimulating 
surfaces.
    (d) Special provisions for manually operated equipment.
    (1) Stimulating probes or clamps shall be stored in a sanitary 
container which is insulated with a material approved by the 
Administrator.\1\
---------------------------------------------------------------------------

    \1\ A list of approved insulation materials is available upon 
request from the Facilities, Equipment and Sanitation Division, 
Technical Services, Food Safety and Inspection Service, U.S. Department 
of Agriculture, Washington, DC 20250.
---------------------------------------------------------------------------

    (2) The electric wires attached to a clamp or probe shall not allow 
for contact between the probe or clamp and an electrical ground and 
shall not extend outside the enclosure.

[53 FR 46432, Nov. 17, 1988, as amended at 64 FR 56415, Oct. 20, 1999]

                           PART 308 [RESERVED]